{"product_id":"valcourt-dallaire-ii-wood-burning-fireplace-fp18r","title":"Valcourt Dallaire II Wood Burning Fireplace - FP18R","description":"\u003ch2\u003e\u003cspan\u003eValcourt Dallaire II Wood Burning Fireplace — FP18R\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Valcourt Dallaire II Wood Burning Fireplace (FP18R) embodies comfort, refinement and high-efficiency performance. Expertly crafted in Canada, this premium wood burning fireplace features retractable cast iron doors that slide discreetly to each side, creating a stunning, unobstructed view of the flames. Designed for both elegance and functionality, it enhances any living space while delivering powerful, reliable heat.\u003c\/p\u003e\n\u003cp\u003eRated for 750 to 2,500 square feet at a maximum output of 85,000 BTU\/h, the Dallaire II offers long-lasting, efficient combustion with the doors closed, or an authentic open-hearth experience when paired with the optional firescreen (AC01226). With customizable louvre styles and optional ROBAX® NightFlame ceramic glass, this built-in fireplace blends timeless craftsmanship with modern innovation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetractable cast iron doors\u003c\/strong\u003e — a sliding door system that gives a full, unobstructed flame view.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-efficiency wood heating\u003c\/strong\u003e — 750 to 2,500 sq ft at up to 85,000 BTU\/h, with a 71.6% optimum overall efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen or closed door operation\u003c\/strong\u003e — efficient combustion when closed; authentic open-fire ambiance with the optional firescreen (AC01226).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustomizable faceplate (5 louvre styles)\u003c\/strong\u003e — personalize the fireplace to match your décor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional ROBAX® NightFlame ceramic glass\u003c\/strong\u003e — conceals the firebox when not in use and gives a clear flame view while burning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e176 CFM blower\u003c\/strong\u003e, with optional fresh air intake, forced air and gravity hot air kits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Canadian craftsmanship\u003c\/strong\u003e — durable materials and precision engineering for long-lasting performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElegant built-in design\u003c\/strong\u003e — zero clearance at the back, sides and floor, for luxury hearth installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat to Order With It\u003c\/h3\u003e\n\u003cp\u003eThe Dallaire II FP18R needs a faceplate and a faceplate louver to be complete. Choose from each required group below.\u003c\/p\u003e\n\u003cp\u003eOsburn and Valcourt are both built by SBI and share many parts, so some links below open our Osburn listing for the same part number.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequired – faceplate:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\nBlack Square Faceplate (VA18FL07)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRequired – faceplate louver (choose one):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\nClassique Style Faceplate Louver (VA18L06)\u003c\/li\u003e\n\u003cli\u003e\nArabesque Style Faceplate Louver (VA18L07)\u003c\/li\u003e\n\u003cli\u003e\nUrban Style Faceplate Louver (VA18L08)\u003c\/li\u003e\n\u003cli\u003e\nMission Style Faceplate Louver (VA18L09)\u003c\/li\u003e\n\u003cli\u003e\nCrown Style Faceplate Louver (VA18L10)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOptional:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\nFirescreen Door (AC01226)\u003c\/li\u003e\n\u003cli\u003e\nSemi-Transparent Black Glass with Nightflame Effect (Set of 2) (AC02774)\u003c\/li\u003e\n\u003cli\u003e\nForced Air Kit (VA4460)\u003c\/li\u003e\n\u003cli\u003e\n6\" x 25' Insulated Flex Pipe for Forced Air Kit (AC01350)\u003c\/li\u003e\n\u003cli\u003e\nTraditional Gravity Kit (AC01375)\u003c\/li\u003e\n\u003cli\u003e\nHeat Shield for Surround\/Shelf (AC01223)\u003c\/li\u003e\n\u003cli\u003e\n4\" Fresh Air Intake Register with Airtight Damper (AC01347)\u003c\/li\u003e\n\u003cli\u003e\n4\" x 10' Insulated Flex Pipe for Fresh Air Intake (AC02091)\u003c\/li\u003e\n\u003cli\u003e\nFireplace Carrying Handles (AC09200)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePerformance\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum heat output (dry cordwood)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e85,000 BTU\/h (24.9 kW)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall heat output range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e25,900 – 78,200 BTU\/h (7.6 – 22.9 kW)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended heating area\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e750 – 2,500 sq ft (70 – 232 m²)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage overall efficiency (HHV)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e65%\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum overall efficiency\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e71.6%\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage particulate emissions\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.9 g\/h (EPA \/ CSA B415.1-10)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage carbon monoxide\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.7 g\/min\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum burn time\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8 hours\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall firebox volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3.04 cu ft (0.086 m³)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA usable firebox volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.61 cu ft (0.074 m³)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended log length\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16\" (406 mm), loaded east-west\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUp to 176 CFM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFraming Dimensions\u003c\/h3\u003e\n\u003cp\u003eGive these to your builder before framing. Note the taller header height on this model, and the alternate widths — a fresh air intake or a forced air kit needs a wider framed opening for a centred installation:\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFraming width — standard\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e41 7\/8\" (1,062 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFraming width — with fresh air intake\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e60 3\/4\" (1,543 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFraming width — with forced air kit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e72 3\/4\" (1,848 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight to first header\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e49 5\/8\" (1,260 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFraming depth\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 1\/2\" (622 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal framing height\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e80\" (2,032 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eClearances to Combustible Material\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum mantel depth\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\" (76 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum mantel distance from the door opening\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8\" (203 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSide wall, measured from the door opening\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e21\" (533 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum distance to the wall in front\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e36\" (914 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum ceiling height, measured from the base of the fireplace\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e80\" (2,032 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure — back, sides and floor beneath the fireplace\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0\" (zero clearance)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney clearance to combustibles\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2\" (51 mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum chimney height\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15' (4.6 m)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe \u003cstrong\u003e21\" side wall clearance\u003c\/strong\u003e is considerably more generous than the Lafayette II's 13\", so the Dallaire II needs a wider wall than its framing width alone suggests. Worth checking early.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"table-block\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion technology\u003c\/td\u003e\n\u003ctd\u003eNon-catalytic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-efficiency certified appliance\u003c\/td\u003e\n\u003ctd\u003eYes, EPA 2020 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel type\u003c\/td\u003e\n\u003ctd\u003eDry cordwood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum log length\u003c\/td\u003e\n\u003ctd\u003e20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog positioning\u003c\/td\u003e\n\u003ctd\u003eLoading over width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChimney diameter\u003c\/td\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlue outlet diameter\u003c\/td\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of chimney\u003c\/td\u003e\n\u003ctd\u003eUL 103 HT (2100 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum chimney height (feet)\u003c\/td\u003e\n\u003ctd\u003e15'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaffle type\u003c\/td\u003e\n\u003ctd\u003eC-Cast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproved for a mobile home installation\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e525 lb (238 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor type\u003c\/td\u003e\n\u003ctd\u003eDouble, retractable, glass with cast iron frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass type\u003c\/td\u003e\n\u003ctd\u003eCeramic glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass surface – dimensions (Width X Height)\u003c\/td\u003e\n\u003ctd\u003e18 3\/4\" X 11\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass air-wash system\u003c\/td\u003e\n\u003ctd\u003eN.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e49 1\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e41 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e29\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor opening – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e9 5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDoor opening - dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e20 3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox – dimension (Height)\u003c\/td\u003e\n\u003ctd\u003e16 7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox – dimension (Width)\u003c\/td\u003e\n\u003ctd\u003e18 3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirebox – dimension (Depth)\u003c\/td\u003e\n\u003ctd\u003e17\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoulded refractory bricks\u003c\/td\u003e\n\u003ctd\u003eN.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStainless-steel secondary-air system improving gas combustion\u003c\/td\u003e\n\u003ctd\u003eN.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA standard (emissions)\u003c\/td\u003e\n\u003ctd\u003eEPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA standard (safety)\u003c\/td\u003e\n\u003ctd\u003eUL 127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTested and listed as per applicable standards\u003c\/td\u003e\n\u003ctd\u003eBy an accredited laboratory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\/Documents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/46400ia_2024-11-25.pdf\" rel=\"noopener\"\u003eInstallation and Operation Manual (46400)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/fp18r-dallaire-ii.pdf\" rel=\"noopener\"\u003eDimension Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Valcourt","offers":[{"title":"Default Title","offer_id":43481297584337,"sku":"FP18R","price":5289.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0628\/5272\/6993\/files\/Valcourt-Dallaire-II-Wood-Burning-Fireplace-FP18R-Valcourt-Dreamwood-Living-152692040.jpg?v=1793736614","url":"https:\/\/bbqgenerals.com\/products\/valcourt-dallaire-ii-wood-burning-fireplace-fp18r","provider":"BBQ Generals","version":"1.0","type":"link"}